Certifications

CERTIFICATIONS

Atos is certified according to the main international standards with the application of IATF automotive methods

QUALITY

UNI EN ISO 9001:2015
Quality Management System certification

HEALTH SAFETY ENVIRONMENT

ISO 14001:2015
Environmental Management System certification
ISO 45001:2018
Occupational, Health & Safety Management System certification
REACH STATEMENT
Atos’ statement about EU regulation REACH for Registration, Evaluation, Authorization and restriction of Chemicals in compliance with 1907/2006/EC

ATEX

ATEX 2014/34/EU Production Quality Assurance Notification - QAN
Notification of the production quality system according to Annex IV of the Directive 2014/34/EU.
ATEX 2014/34/EU EN ISO 80079-36, EN ISO 80079-37
Ex-proof vane pumps type PFEA and AXIAL piston pumps type PVPCA for surface plants with gas, vaporous, mists and dust Zone 1, 2, 21 and 22
Ex II 2/2G Ex h IIC T5, T4 Gb
Ex II 2/2D Ex h IIIC T100°C, T135°C Db
ATEX 2014/34/EU EN ISO 80079-36, EN ISO 80079-37
Ex-proof locations cylinders type CKA and servocylinders type CKAM for surface plants with gas, vaporous, mists and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex h IIC T6, T4 Gb
Ex II 2D Ex h IIIC T85°C, T135°C Db
ATEX 2014/34/EU EN IEC 60079-0, EN 60079-1, EN 60079-31
Ex-proof on-off, proportional and stainless steel solenoids for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex db IIC T6,T4,T3 Gb
Ex II 2D Ex tb IIIC T85°C, T135°C, T200°C Db IP66/67
ATEX 2014/34/EU EN IEC 60079-0, EN 60079-1, EN 60079-31
Ex-proof position transducers LVDT for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex db IIC T6, T5, T4 Gb IP66/67
Ex II 2D Ex tb IIIC T85°C, T100°C, T135°C Db IP66/67
ATEX 2014/34/EU EN IEC 60079-0 and EN 60079-1
Ex-proof on-off and proportional solenoids for mines and surface installations with grisou and or flammable dust
Ex I M2 Ex db I Mb IP66/67
ATEX 2014/34/EU EN IEC 60079-0 and EN 60079-1, EN 60079-31
Ex-proof proportional solenoids with on-board digital electronics for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex II 2G Ex db IIC T6…T4 Gb
Ex II 2D Ex tb IIIC T85°C...T135°C Db IP66/67
ATEX 2014/34/EU EN 60079-0, EN 60079-11, EN 60079-26
On-off intrinsically safe solenoids for surface plants with gas or vaporous - Zone 0, 1 and 2 or mines with grisou and flammable dust
Ex I M2 Ex ia I Mb / Ex ib I Mb Tamb.: -20°C ÷ +60°C
Ex II 1G Ex ia IIC T6 Ga or II 1G Ex ia IIB T6 Ga or II 1G Ex ia IIA T5 Ga
Tamb.: -20°C ÷ +60°C or -40°C ÷ +60°C
ATEX 2014/34/EU EN IEC 60079-0, EN 60079-1, EN 60079-31
Ex-proof position transducers LVDT ETHA-15 for mining and surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
II 2G Ex db IIC T6 Gb
Il 2D Ex tb IIIC T85°C Db
I M2 Ex db I Mb

IECEx

IECEx Qualty Assessment Report
IECEx Certification scheme for Explosive atmospheres IEC 600079-0, IEC60079-1, IEC 600079-31
Ex-proof on-off, proportional and stainless steel solenoids for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex db IIC T6 or T4 or T3 Gb
Ex tb IIIC T85°C or T135°C or T200°C Db IP 66/67
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-1
Ex-proof on-off and proportional solenoids for mines and surface installations with grisou and or flammable dust
Ex db I Mb IP66/67
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-1, IEC 60079-31
Ex-proof position transducers LVDT for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex db IIC T6 or T5 or T4 Gb
Ex tb IIIC T85°C or T100°C or T135°C Db IP 66/67
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-1, IEC 60079-31
Ex-proof proportional solenoids with on-board digital electronics for surface plants with gas, vaporous and dust - Zone 1, 2, 21 e 22
Ex db IIC T6...T4 Gb
Ex tb IIIC T85°C...T135°C Db IP66/67b
IECEx Certification scheme for Explosive atmospheres IEC 60079-0, IEC 60079-11, IEC 60079-26
On-off intrinsically safe solenoids for surface plants with gas or vaporous - Zone 0, 1 and 2 or mines with grisou and or flammable dust
Ex ia IIC T6 Ga or Ex ia IIB T6 Ga or Ex ia IIA T5 Ga
Ex ia I Mb / Ex ib I Mb
IECEx certification scheme for explosive atmospheres IEC 60079-0, IEC 60079-1, IEC 60079-31
Ex-proof position transducers LVDT ETHA-15 for mining and surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
Ex db I Mb

CCC

CCC Ex China Compulsory Certification CNCA-C23-01:2019 GB 3836.1, GB 3836.2, GB 12476.1, GB 12476.5
Ex-proof on-off, proportional and stainless steel solenoids for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex d IIC T6/T4/T3 Gb
Ex tD A21 IP66/IP67 T85°C/T135°C/T200°C
CCC Ex China Compulsory Certification CNCA-C23-01:2019 GB 3836.1, GB 3836.2, GB12476.1, GB 12476.5
Ex-proof position transducers LVDT for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex d IIC T6/T5/T4 Gb
Ex tD A21 IP66/67 T85°C/T100°C/T135°C
CCC Ex China Compulsory Certification CNCA-C23-01:2019 GB 3836.1, GB 3836.2, GB12476.1, GB 12476.5
Ex-proof proportional solenoids with on-board digital electronics for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex d IIC T6/T5/T4 Gb
Ex tD A21 IP66/67 T85°C/T100°C/T135°C
CCC Ex China Compulsory Certification CNCA-C23-01:2019 GB 3836.1, GB 3836.2, GB12476.1, GB 12476.5
Ex-proof position transducers LVDT ETHA-15 for surface plants with gas, vaporous and dust - Zone 1, 2, 21 and 22
Ex d IIC T6 Gb
Ex tD A21 IP66/67 T85°C

EAC

EAC Ex certification for hazardous environments
Ex-proof valves, pumps, electronic drivers, transducers and cylinders for surface plants in presence of gas, vaporous and dust.
EAC EurAsian economic union declaration of Conformity
Valves, pumps, electronic drivers, transducers, filters and cylinders conforming to TR certification system adopted in the Customs Union countries of Russia, Belarus, Kazakhstan, Armenia and Kyrgyzstan.

cULus

American and Canadian Standard UL 1203 & CSA 22.2 - cULus listed
Ex-proof on-off, proportional and stainless steel solenoids for flammable gas or vapor
Class I Div 1 Groups C & D, Temperature class T6, T5, T4 and T3
American and Canadian Standard UL 429 & CSA 22.2
Recognized component mark - UR marked Coils

PESO

PESO Petroleum and Explosive Safety organization - INDIA
Ex-proof on-off and proportional solenoids for surface plants with gas - Zone 1
Ex db IIC T6,T4,T3 Gb
PESO Petroleum and Explosive Safety organization - INDIA
Ex-proof stainless steel solenoids for surface plants with gas - Zone 1
Ex db IIC T6,T4,T3 Gb

MA

Directional and pilot operated pressure relief valves equipped with explosion-proof solenoids certified according MA mining certification
ON REQUEST

PED

PED 2014/68/UE for valves and cartridges
Pressure equipment directive
Valve type CART M-3, M-5, M-6, ARE-15, ARE-20, ARE-6, ARE-15, AGAM and ARAM Standard steel and stainless steel executions
PED 2014/68/UE for design control
Certification CE/PED of projects
PED 2014/68/UE for hydraulic power stations with safety functions
Certification CE/PED of power packs
PED 2014/68/UE for accumulators group
Certification CE/PED of accumulators group

SAFETY

SAFETY VALVES 2006/42/CE, EN ISO 13849-1, EN ISO 13849-2
Safety components according to the machine directive
Direct, piloted operated valves and cartridges with mechanical micro switch or inductive proximity sensor or inductive position sensors
HYDRAULICS BLOCKS 2006/42/CE, EN ISO 13849-1, EN ISO 13849-2
Directive for downstroking Press Brakes - metal forming
Standard PBAC and PBBC solutions for CNC synchronized press brakes - TÜV certified
HYDRAULICS BLOCKS 2006/42/CE, EN ISO 13849-1, EN ISO 13849-2
Directive for downstroking Press Brakes - metal forming
Standard solution for bending press (not CNC) - TÜV certified
SIL compliance IEC EN 61508
Direct operated solenoid valves, poppet type and spool type
SIL compliance IEC EN 61508
Intrinsically safe direct operated solenoid valves, spool type
SIL compliance IEC EN 61508
Hydraulic operated stainless steel poppet valves
SAFETY CERTIFIED DIGITAL PROPORTIONAL VALVES
TÜV certified components according to EN IEC 61508 (SIL) and EN ISO 13849 (PL)
ON REQUEST